MS048: Measurement differences between air temperature instruments used at H.J. Andrews meteorological stations
Notice
"As Is" Basis: All content, including maps and forecasts, is provided without warranties. Users are advised to independently verify critical information.
Citation
Daly, C. 2020. Measurement differences between air temperature instruments used at H.J. Andrews meteorological stations Long-Term Ecological Research Andrews Forest LTER Site. [Database]. Available: https://andrewsforest-stage.forestry.oregonstate.edu/data/fsdb-data-catalog/MS048 Accessed 2026-05-10.
Abstract
The PRIMET Horizontal Radiation Shield Comparison (PHRSC) experiment compares the difference between the air temperature measurements of a reference temperature sensor inside a fan aspirated radiation shield and temperature sensors located inside passively aspirated radiation shields including a cotton region shelter, Gill multi-plate shield, and a custom-fabricated model. Observed variables include air temperature, wind speed, and incoming and reflected solar radiation. Data was collected in the field between 2010 and 2017 at the Primary Meteorological Station (PRIMET) at H.J. Andrews Experimental Forest, located in Oregon’s Western Cascades (44.21, -122.26, elevation 430m).
Coverage
Temporal coverage: 2010-07-30 to 2017-04-27
Geographic coverage: H.J. Andrews Experimental Forest, Western Cascades, Oregon, Primary Meteorological Station
Spatial coverage:
Bounds: W -122.25594100, E -122.25594100, N 44.21189300, S 44.21189300
Purpose
- To examine the measurement differences between air temperature instruments that are using the same sensor but different radiation shields. These measurement differences are examined for various temperature statistics (average, minimum, maximum) at varying temporal resolutions. This information will help researchers understand the magnitude of measurement bias associated with instruments that have been used to record air temperature at H.J. Andrews meteorological stations over time. This bias can have implications during analysis when air temperature data from different instruments is combined into one dataset without accounting for differences between air temperature methods.
Project
Title: Long-Term Ecological Research
Personnel
-
Sherri L. Johnson - Principal Investigator US Forest Service ;Pacific NW Research Station ;3200 SW Jefferson Way, Corvallis, OR, 97331, USAPhone: 541-758-7771Email: sherri.johnson2@usda.gov, sherri.johnson@oregonstate.edu
-
Julia A. Jones - Principal Investigator Oregon State University;Department of Geosciences; Wilkinson Hall 104, Corvallis, OR, 97331-5506, USAPhone: (541) 737-1224Email: Julia.Jones@oregonstate.edu, geojulia@comcast.netORCID: http://orcid.org/0000-0001-9429-8925
-
Matthew G Betts - Principal Investigator Department of Forest Ecosystems and Society; 201E Richardson Hall; College of Forestry; Oregon State University, Corvallis, OR, 97331Phone: (541) 737-3841Email: matt.betts@oregonstate.edu
-
Michael P. Nelson - Principal Investigator Department of Forest Ecosystems and Society; 201K Richarson Hall; College of Forestry; Oregon State University, Corvallis, OR, 97331Phone: 541-737-9221Email: mpnelson@oregonstate.eduORCID: http://orcid.org/0000-0001-6917-4752
-
David Bell - Principal Investigator Email: david.bell@usda.gov, david.bell@oregonstate.edu
Abstract
- The H.J. Andrews Experimental Forest is a living laboratory that provides unparalleled opportunities for the study of forest and stream ecosystems in the central Cascade Range of Oregon. Since 1980, as a part of the National Science Foundation Long Term Ecological Research (NSF-LTER) program, the Andrews Experimental Forest has become a leader in the analysis of forest and stream ecosystem dynamics.
- Long-term field experiments and measurement programs have focused on climate dynamics, streamflow, water quality, and vegetation succession. Currently researchers are working to develop concepts and tools needed to predict effects of natural disturbance, land use, and climate change on ecosystem structure, function, and species composition.
- The Andrews Experimental Forest is administered cooperatively by the USDA Forest Service Pacific Northwest Research Station, Oregon State University and the Willamette National Forest. Funding for the research program comes from the National Science Foundation (NSF), US Forest Service Pacific Northwest Research Station, Oregon State University, and other sources.
Funding
Data were provided by the HJ Andrews Experimental Forest research program, funded by the National Science Foundation's Long-Term Ecological Research Program (DEB 1440409), US Forest Service Pacific Northwest Research Station, and Oregon State University. National Science Foundation: DEB1440409
Study Area Description
-
Long-Term Ecological Research The Andrews Forest is situated in the western Cascade Range of Oregon, and covers the entire 15,800-acre (6400-ha) drainage basin of Lookout Creek. Elevation ranges from 1350 to 5340 feet (410 to 1630 m). Broadly representative of the rugged mountainous landscape of the Pacific Northwest, the Andrews Forest contains excellent examples of the region's conifer forests and associated wildlife and stream ecosystems. These forests are among the tallest and most productive in the world, with tree heights of often greater than 250 ft (75 m). Streams are steep, cold and clean, providing habitat for numerous aquatic organisms.
Associated Party
-
Mark D Schulze
Role: Principal InvestigatorH.J. Andrews Experimental Forest; PO Box 300, Blue River, OR, 97413Phone: 541-822-6336Email: mark.schulze@oregonstate.edu
-
Sherri L. Johnson
Role: Other ResearcherUS Forest Service ;Pacific NW Research Station ;3200 SW Jefferson Way, Corvallis, OR, 97331, USAPhone: 541-758-7771Email: sherri.johnson2@usda.gov, sherri.johnson@oregonstate.edu
-
Stephanie A Schmidt
Role: Other ResearcherDepartment of Forest Ecosystems and Society; Oregon State University, Corvallis, Oregon, 97331Email: stephanie.schmidt@oregonstate.edu
-
Adam M Kennedy
Role: Other ResearcherCorvallis, OR, 97331, USEmail: adam.kennedy@oregonstate.edu
-
Greg M Cohn
Role: Other ResearcherUSFS Rd 15-130-132, Blue River, OR, 97413Phone: 541-822-6305Email: cohng@oregonstate.edu
-
John Moreau
Role: Former InvestigatorH.J. Andrews Experimental Forest;Box 300, Blue River, OR, 97413, USAEmail: moreauj@fsl.orst.edu
-
Frederick A. Bierlmaier
Role: Former InvestigatorOR, USA
-
Christopher Daly
Role: CreatorPRISM Group;Northwest Alliance for Computational Science and Engineering, 2000 Kelley Engineering Center;Oregon State University, Corvallis, OR, 97331, USAPhone: (541) 737-2531Email: daly@nacse.org
Contact
-
Information Manager
Andrews Forest LTER Program, US Forest Service Pacific Northwest Research Station, 3200 SW Jefferson Way, Corvallis, OR, 97331Email: hjaweb@fsl.orst.edu
-
Mark D Schulze
H.J. Andrews Experimental Forest; PO Box 300, Blue River, OR, 97413Phone: 541-822-6336Email: mark.schulze@oregonstate.edu
Publisher
-
Andrews Forest LTER Site
Role: PublisherForest Ecosystems and Society Department in Forestry, Oregon State University, 201K Richardson Hall, Corvallis, OR, 97331-5752Phone: (541) 737-8480Email: lterweb@fsl.orst.edu
Study Description
The PRIMET Horizontal Radiation Shield Comparison (PHRSC) experiment compares the difference between the air temperature measurements of a reference temperature sensor inside a fan aspirated radiation shield and temperature sensors located inside passively aspirated radiation shields including a cotton region shelter, Gill multi-plate shield, and a custom-fabricated model. Observed variables include air temperature, wind speed, and incoming and reflected solar radiation. Data was collected in the field between 2010 and 2017 at the Primary Meteorological Station (PRIMET) at H.J. Andrews Experimental Forest, located in Oregon’s Western Cascades (44.21, -122.26, elevation 430m). To examine the measurement differences between air temperature instruments that are using the same sensor but different radiation shields. These measurement differences are examined for various temperature statistics (average, minimum, maximum) at varying temporal resolutions. This information will help researchers understand the magnitude of measurement bias associated with instruments that have been used to record air temperature at H.J. Andrews meteorological stations over time. This bias can have implications during analysis when air temperature data from different instruments is combined into one dataset without accounting for differences between air temperature methods. Quality Assurance - MS048
Purpose: To examine the measurement differences between air temperature instruments that are using the same sensor but different radiation shields. These measurement differences are examined for various temperature statistics (average, minimum, maximum) at varying temporal resolutions. This information will help researchers understand the magnitude of measurement bias associated with instruments that have been used to record air temperature at H.J. Andrews meteorological stations over time. This bias can have implications during analysis when air temperature data from different instruments is combined into one dataset without accounting for differences between air temperature methods.
Methods
Method Steps
Method Step 1
No method step description paragraphs listed.
Instrumentation:
- <para>Four air temperature instruments all used the same Campbell Scientific 107 thermistor sensor (Sensor accuracy: +/-0.2 deg C between 0 and 60; +/-0.4 deg C below 0 to -35) and four different radiation shields: </para> <para>1) fan-aspirated (ASP or aspirated) - R.M. Young 43502-L compact aspirated shield (shield radiation error <0.2 deg C @ 1000 W/m2) </para> <para>2) cotton region shelter (CRS) - NovaLynx 380-605 large instrument shelter (no accuracy information available) </para> <para>3) Gill multi-plate (Gill) - R.M. Young 41303-5A 6-plate solar radiation shield (no accuracy information available) </para> <para>4) a custom-fabricated shield developed by staff at the research site (HJA) - 8-inch long, 3.5 inch diameter, schedule 40 PVC pipe split in half lengthwise over PVC tubing containing sensor (no accuracy information available) </para> <para>One propeller anemometer was used to measure wind speed - R.M. Young 05103 (Resolution: 1.0 m/s ; accuracy: +/-0.3 m/s or 1% of reading) </para> <para>One upward-facing pyranometer measured incoming solar radiation (ISR), and one down-facing pyranometer measured reflected solar radiation – both CM3 Kipp & Zonen (Response time: 18s; spectral range 305-2800 nm; sensitivity: 10-35 micro V/W/m2; error: +/-25 W/m2) </para> <para>All sensors were connected to the same data logger - Campbell Scientific CR1000 </para> <para>None of the instruments were calibrated during the course of the study. </para>
Quality Assurance - MS048
- Air temperature, incoming and reflected solar radiation, and wind speed data were collected continuously between July 2010 and April 2017. Measurements were taken every 15 seconds, and the average for a 15-minute period (60 observations) was recorded (referred to hereafter as “15-minute average observations”). Additionally, from April 2015 to April 2017, measurements were taken every 15 seconds, and for each 5-minute period (20 observations), the maximum and minimum air temperature and maximum incoming and reflected solar radiation and wind speed were recorded (referred to hereafter as “5-minute observations” with the relevant statistic specified).
- All data were reviewed for quality control using an automated process (GCE Data Toolbox Version 3.9.4b - https://gce-lter.marsci.uga.edu/public/im/tools/data_toolbox.htm). Rows with missing observations for aspirated air temperature, incoming solar radiation, reflected solar radiation, or wind speed were removed, with a total of 6,097 rows (out of 210,504) removed from the 15-minute data and 8,358 rows (out of 210,792) removed from the 5-minute data. Data logger issues from February 27-March 7, 2013 and August 2-31 in 2016 caused most missing values.
Sampling
Study Extent
- The study was located at the Primary Meteorological Station (PRIMET) at H.J. Andrews Experimental Forest, located in Oregon’s Western Cascades (44.21, -122.26, elevation 430m). PRIMET is sited in a relatively flat clearing approximately 29 x 23 m2 in size, with conifer forests outside the perimeter. It is located in the bottom of a valley with steep ridges to the southeast and northwest. Annual precipitation averages 2200 mm and occurs primarily November through May. Snow can accumulate at this site in winter, but it does not remain for long periods. Summers are generally dry and warm, with cool nights and occasional thunderstorms.
- Sampling frequency: 15 and 5 minute
Sampling Description
- Instruments measuring air temperature, wind speed, incoming solar radiation and reflected solar radiation were placed side-by-side at 1.5m above the ground. There were four air temperature instruments, all using an identical sensor (Campbell Scientific 107 thermistor) but different radiation shields: 1) fan-aspirated (ASP or aspirated), 2) cotton region shelter (CRS), 3) Gill multi-plate (Gill), and 4) a custom-fabricated shield developed by staff at the research site (HJA). One propeller anemometer was used to measure wind speed. One upward-facing pyranometer measured incoming solar radiation (ISR), and one down-facing pyranometer measured reflected solar radiation (RSR). All sensors were connected to the same Campbell Scientific CR1000 data logger.
Spatial Sampling Units
-
Primary Meteorological Station
W -122.25594100, E -122.25594100, N 44.21189300, S 44.21189300Altitude: 436 to 436 meter
-
Andrews Experimental Forest (HJA)
W -122.26172200, E -122.10084700, N 44.28196400, S 44.19770400Altitude: 1631 to 1631 meter
Software
No software entries listed in this EML file.
Keywords
- LTER controlled vocabulary: air temperature (theme), maximum temperature (theme)
Taxonomic Hierarchy
No taxonomic hierarchy listed in this EML file.
Data Entities
| # | Entity | Metadata | Data |
|---|---|---|---|
| 1 |
MS04801
MS04801 Mean air temperature over a 15-minute interval: Contains mean air temperature measurements over a 15-minute interval for four different radiation shields |
METADATA | DATA |
| 2 |
MS04802
MS04802 Mean incoming solar radiation, reflected solar radiation, and horizontal wind speed over a 15-minute interval: Contains mean incoming solar radiation, reflected solar radiation, and wind speed measurements over a 15-minute interval |
METADATA | DATA |
| 3 |
MS04803
MS04803 Mean, minimum, and maximum air temperature over a 5-minute interval: Contains mean, minimum, and maximum air temperature measurements over a 5-minute interval for four different radiation shields |
METADATA | DATA |
| 4 |
MS04804
MS04804 Mean and maximum incoming solar radiation, reflected solar radiation, and horizontal wind speed over a 5-minute interval: Contains mean and maximum incoming solar radiation, reflected solar radiation and wind speed measurements over a 5-minute interval |
METADATA | DATA |
Metadata
MS04801 - MS04801
Object name: MS04801.csv
Records: 236394
Attributes: 12
Temporal coverage: 2010-07-30 to 2017-04-27
File size: 15120184 byte
Checksum (MD5): 90094e166e762f366aa2b82c9bea9a0e
Format: headers=1, recordDelimiter=\r\n, fieldDelimiter=,, quoteCharacter=", orientation=column
Constraints (2)
-
primaryKey: PRIMARY MS04801.DATE_TIME, MS04801.SITE
-
notNullConstraint: NOTNULL MS04801.ASPIRATED_MEAN_FLAG, MS04801.CRS_MEAN_FLAG, MS04801.DATE_TIME, MS04801.DBCODE, MS04801.ENTITY, MS04801.GILL_MEAN_FLAG, MS04801.HJA_MEAN_FLAG, MS04801.SITE
Attributes (12)
DBCODE - char(5) (nominal)
ID: MS04801.DBCODE
FSDB Database Code (MS048)
Type system: Microsoft SQL Server 2008
Code definitions (1)
-
MS048
FSDB Database Study Code
ENTITY - numeric(2,0) (ratio)
ID: MS04801.ENTITY
Entity number
Type system: Microsoft SQL Server 2008
Unit: number
Precision: 1
Numeric domain: type=natural, min=1.0000 (exclusive=false), max=1.0000 (exclusive=false)
SITE - char(6) (ordinal)
ID: MS04801.SITE
Site where data collected
Type system: Microsoft SQL Server 2008
Code definitions (1)
-
PRIMET
Primary Meteorological Station
DATE_TIME - datetime (dateTime)
ID: MS04801.DATE_TIME
Date and time collected
Type system: Microsoft SQL Server 2008
Date format: YYYY-MM-DD hh:mm:ss
ASPIRATED_MEAN - numeric(5,1) (ratio)
ID: MS04801.ASPIRATED_MEAN
Mean air temperature measurement for interval sampled by a Campbell Scientific model 107 thermistor housed in a R.M. Young Model 43502-L compact aspirated shield at 150 cm height
Type system: Microsoft SQL Server 2008
Unit: degrees Celsius
Precision: 1
Numeric domain: type=real, min=-16.1000 (exclusive=false), max=40.4000 (exclusive=false)
ASPIRATED_MEAN_FLAG - char(1) (nominal)
ID: MS04801.ASPIRATED_MEAN_FLAG
Rows flagged for QA issues, including missing and out of range values
Type system: Microsoft SQL Server 2008
Code definitions (3)
-
A
Accepted value has passed all QC tests applied as represented by the quality level
-
M
Missing value
-
Q
Questionable value, including out of range values
CRS_MEAN - numeric(5,1) (ratio)
ID: MS04801.CRS_MEAN
Mean air temperature measurement for interval sampled by a Campbell Scientific model 107 thermistor housed in a NovaLynx 380-605 large instrument (cotton region) shelter at 150 cm height
Type system: Microsoft SQL Server 2008
Unit: degrees Celsius
Precision: 1
Numeric domain: type=real, min=-16.8000 (exclusive=false), max=41.5000 (exclusive=false)
CRS_MEAN_FLAG - char(1) (nominal)
ID: MS04801.CRS_MEAN_FLAG
Rows flagged for QA issues, including missing and out of range values
Type system: Microsoft SQL Server 2008
Code definitions (3)
-
A
Accepted value has passed all QC tests applied as represented by the quality level
-
M
Missing value
-
Q
Questionable value, including out of range values
GILL_MEAN - numeric(5,1) (ratio)
ID: MS04801.GILL_MEAN
Mean air temperature measurement for interval sampled by a Campbell Scientific model 107 thermistor housed in a R.M. Young 41303-5A 6-plate radiation shield at 150 cm height
Type system: Microsoft SQL Server 2008
Unit: degrees Celsius
Precision: 1
Numeric domain: type=real, min=-17.0000 (exclusive=false), max=41.5000 (exclusive=false)
GILL_MEAN_FLAG - char(1) (nominal)
ID: MS04801.GILL_MEAN_FLAG
Rows flagged for QA issues, including missing and out of range values
Type system: Microsoft SQL Server 2008
Code definitions (3)
-
A
Accepted value has passed all QC tests applied as represented by the quality level
-
M
Missing value
-
Q
Questionable value, including out of range values
HJA_MEAN - numeric(5,1) (ratio)
ID: MS04801.HJA_MEAN
Mean air temperature measurement for interval sampled by a Campbell Scientific model 107 thermistor housed in a locally designed radiation shield at 150 cm height (8-inch long, 3.5 inch diameter, schedule 40 PVC pipe split in half lengthwise
Type system: Microsoft SQL Server 2008
Unit: degrees Celsius
Precision: 1
Numeric domain: type=real, min=-17.1000 (exclusive=false), max=43.0000 (exclusive=false)
HJA_MEAN_FLAG - char(1) (nominal)
ID: MS04801.HJA_MEAN_FLAG
Rows flagged for QA issues, including missing and out of range values
Type system: Microsoft SQL Server 2008
Code definitions (3)
-
A
Accepted value has passed all QC tests applied as represented by the quality level
-
M
Missing value
-
Q
Questionable value, including out of range values
MS04802 - MS04802
Object name: MS04802.csv
Records: 236394
Attributes: 10
Temporal coverage: 2010-07-30 to 2017-04-27
File size: 12543812 byte
Checksum (MD5): d47eed294df6edd0b52f77eb7ae465f1
Format: headers=1, recordDelimiter=\r\n, fieldDelimiter=,, quoteCharacter=", orientation=column
Constraints (2)
-
primaryKey: PRIMARY MS04802.DATE_TIME, MS04802.SITE
-
notNullConstraint: NOTNULL MS04802.DATE_TIME, MS04802.DBCODE, MS04802.ENTITY, MS04802.REF_SOLAR_MEAN_FLAG, MS04802.SITE, MS04802.SOLAR_MEAN_FLAG, MS04802.WSPD_MEAN_FLAG
Attributes (10)
DBCODE - char(5) (nominal)
ID: MS04802.DBCODE
FSDB Database Code (MS048)
Type system: Microsoft SQL Server 2008
Code definitions (1)
-
MS048
FSDB Database Study Code
ENTITY - numeric(2,0) (ratio)
ID: MS04802.ENTITY
Entity number
Type system: Microsoft SQL Server 2008
Unit: number
Precision: 1
Numeric domain: type=natural, min=2.0000 (exclusive=false), max=2.0000 (exclusive=false)
SITE - char(6) (ordinal)
ID: MS04802.SITE
Site where data collected
Type system: Microsoft SQL Server 2008
Code definitions (1)
-
PRIMET
Primary Meteorological Station
DATE_TIME - datetime (dateTime)
ID: MS04802.DATE_TIME
Date and time collected
Type system: Microsoft SQL Server 2008
Date format: YYYY-MM-DD hh:mm:ss
SOLAR_MEAN - numeric(4,0) (ratio)
ID: MS04802.SOLAR_MEAN
Mean incoming solar radiation for interval is measured by a Kipp and Zonen solar radiation pyranometer, model CM3, with a Campbell Scientific data logger at 150 cm height
Type system: Microsoft SQL Server 2008
Unit: watt per m2
Precision: 1
Numeric domain: type=real, min=0.0000 (exclusive=false), max=1112.0000 (exclusive=false)
SOLAR_MEAN_FLAG - char(1) (nominal)
ID: MS04802.SOLAR_MEAN_FLAG
Rows flagged for QA issues, including missing and out of range values
Type system: Microsoft SQL Server 2008
Code definitions (3)
-
A
Accepted value has passed all QC tests applied as represented by the quality level
-
M
Missing value
-
Q
Questionable value, including out of range values
REF_SOLAR_MEAN - numeric(3,0) (ratio)
ID: MS04802.REF_SOLAR_MEAN
Mean reflected solar radiation for interval is measured by a downward-facing Kipp and Zonen solar radiation pyranometer, model CM3, with a Campbell Scientific data logger at 150 cm height
Type system: Microsoft SQL Server 2008
Unit: watt per m2
Precision: 1
Numeric domain: type=real, min=0.0000 (exclusive=false), max=546.0000 (exclusive=false)
REF_SOLAR_MEAN_FLAG - char(1) (nominal)
ID: MS04802.REF_SOLAR_MEAN_FLAG
Rows flagged for QA issues, including missing and out of range values
Type system: Microsoft SQL Server 2008
Code definitions (3)
-
A
Accepted value has passed all QC tests applied as represented by the quality level
-
M
Missing value
-
Q
Questionable value, including out of range values
WSPD_MEAN - numeric(3,1) (ratio)
ID: MS04802.WSPD_MEAN
Mean wind speed for interval is measured by an RM Young Model 05103 Wind Monitor mounted to the tower at 150 cm with a Campbell Scientific data logger.
Type system: Microsoft SQL Server 2008
Unit: meters per second
Precision: 1
Numeric domain: type=real, min=0.0000 (exclusive=false), max=2.0000 (exclusive=false)
WSPD_MEAN_FLAG - char(1) (nominal)
ID: MS04802.WSPD_MEAN_FLAG
Rows flagged for QA issues, including missing and out of range values
Type system: Microsoft SQL Server 2008
Code definitions (5)
-
A
Accepted value has passed all QC tests applied as represented by the quality level
-
M
Missing value
-
Q
Questionable value, including out of range values
-
B
Wind speed measurement is below or equal to the instrument detection limit of 1 m per second
-
NB
Wind speed measurement is below or equal to 0.3 m per second and is not considered reliable and is below the instrument detection limit of 1 m per second
MS04803 - MS04803
Object name: MS04803.csv
Records: 232174
Attributes: 28
Temporal coverage: 2015-02-10 to 2017-04-01
File size: 26886360 byte
Checksum (MD5): d69f42ce39597ef650bfe78248c695bb
Format: headers=1, recordDelimiter=\r\n, fieldDelimiter=,, quoteCharacter=", orientation=column
Constraints (2)
-
primaryKey: PRIMARY MS04803.DATE_TIME, MS04803.SITE
-
notNullConstraint: NOTNULL MS04803.ASPIRATED_MAX_FLAG, MS04803.ASPIRATED_MEAN_FLAG, MS04803.ASPIRATED_MIN_FLAG, MS04803.CRS_MAX_FLAG, MS04803.CRS_MEAN_FLAG, MS04803.CRS_MIN_FLAG, MS04803.DATE_TIME, MS04803.DBCODE, MS04803.ENTITY, MS04803.GILL_MAX_FLAG, MS04803.GILL_MEAN_FLAG, MS04803.GILL_MIN_FLAG, MS04803.HJA_MAX_FLAG, MS04803.HJA_MEAN_FLAG, MS04803.HJA_MIN_FLAG, MS04803.SITE
Attributes (28)
DBCODE - char(5) (nominal)
ID: MS04803.DBCODE
FSDB Database Code (MS048)
Type system: Microsoft SQL Server 2008
Code definitions (1)
-
MS048
FSDB Database Study Code
ENTITY - numeric(2,0) (ratio)
ID: MS04803.ENTITY
Entity number
Type system: Microsoft SQL Server 2008
Unit: number
Precision: 1
Numeric domain: type=natural, min=3.0000 (exclusive=false), max=3.0000 (exclusive=false)
SITE - char(6) (ordinal)
ID: MS04803.SITE
Site where data collected
Type system: Microsoft SQL Server 2008
Code definitions (1)
-
PRIMET
Primary Meteorological Station
DATE_TIME - datetime (dateTime)
ID: MS04803.DATE_TIME
Date and time collected
Type system: Microsoft SQL Server 2008
Date format: YYYY-MM-DD hh:mm:ss
ASPIRATED_MEAN - numeric(5,1) (ratio)
ID: MS04803.ASPIRATED_MEAN
Mean air temperature measurement for interval sampled by a Campbell Scientific model 107 thermistor housed in a R.M. Young Model 43502-L compact aspirated shield at 150 cm height
Type system: Microsoft SQL Server 2008
Unit: degrees Celsius
Precision: 1
Numeric domain: type=real, min=-13.0000 (exclusive=false), max=226.0000 (exclusive=false)
ASPIRATED_MEAN_FLAG - char(1) (nominal)
ID: MS04803.ASPIRATED_MEAN_FLAG
Rows flagged for QA issues, including missing and out of range values
Type system: Microsoft SQL Server 2008
Code definitions (3)
-
A
Accepted value has passed all QC tests applied as represented by the quality level
-
M
Missing value
-
Q
Questionable value, including out of range values
ASPIRATED_MAX - numeric(5,1) (ratio)
ID: MS04803.ASPIRATED_MAX
Maximum air temperature measurement for a 5-minute interval sampled by a Campbell Scientific model 107 thermistor housed in a R.M. Young Model 43502-L compact aspirated shield at 150 cm height
Type system: Microsoft SQL Server 2008
Unit: degrees Celsius
Precision: 1
Numeric domain: type=real, min=-12.8000 (exclusive=false), max=156.7000 (exclusive=false)
ASPIRATED_MAX_FLAG - char(1) (nominal)
ID: MS04803.ASPIRATED_MAX_FLAG
Rows flagged for QA issues, including missing and out of range values
Type system: Microsoft SQL Server 2008
Code definitions (3)
-
A
Accepted value has passed all QC tests applied as represented by the quality level
-
M
Missing value
-
Q
Questionable value, including out of range values
ASPIRATED_MIN - numeric(5,1) (ratio)
ID: MS04803.ASPIRATED_MIN
Minimum air temperature measurement for a 5-minute interval sampled by a Campbell Scientific model 107 thermistor housed in a R.M. Young Model 43502-L compact aspirated shield at 150 cm height
Type system: Microsoft SQL Server 2008
Unit: degrees Celsius
Precision: 1
Numeric domain: type=real, min=-13.2000 (exclusive=false), max=40.1000 (exclusive=false)
ASPIRATED_MIN_FLAG - char(1) (nominal)
ID: MS04803.ASPIRATED_MIN_FLAG
Rows flagged for QA issues, including missing and out of range values
Type system: Microsoft SQL Server 2008
Code definitions (3)
-
M
Missing value
-
Q
Questionable value, including out of range values
-
A
Accepted value has passed all QC tests applied as represented by the quality level
CRS_MEAN - numeric(5,1) (ratio)
ID: MS04803.CRS_MEAN
Mean air temperature measurement for interval sampled by a Campbell Scientific model 107 thermistor housed in a NovaLynx 380-605 large instrument (cotton region) shelter at 150 cm height
Type system: Microsoft SQL Server 2008
Unit: degrees Celsius
Precision: 1
Numeric domain: type=real, min=-13.3000 (exclusive=false), max=41.7000 (exclusive=false)
CRS_MEAN_FLAG - char(1) (nominal)
ID: MS04803.CRS_MEAN_FLAG
Rows flagged for QA issues, including missing and out of range values
Type system: Microsoft SQL Server 2008
Code definitions (3)
-
A
Accepted value has passed all QC tests applied as represented by the quality level
-
M
Missing value
-
Q
Questionable value, including out of range values
CRS_MAX - numeric(5,1) (ratio)
ID: MS04803.CRS_MAX
Maximum air temperature measurement for a 5-minute interval sampled by a Campbell Scientific model 107 thermistor housed in a NovaLynx 380-605 large instrument (cotton region) shelter at 150 cm height
Type system: Microsoft SQL Server 2008
Unit: degrees Celsius
Precision: 1
Numeric domain: type=real, min=-13.3000 (exclusive=false), max=41.9000 (exclusive=false)
CRS_MAX_FLAG - char(1) (nominal)
ID: MS04803.CRS_MAX_FLAG
Rows flagged for QA issues, including missing and out of range values
Type system: Microsoft SQL Server 2008
Code definitions (3)
-
A
Accepted value has passed all QC tests applied as represented by the quality level
-
M
Missing value
-
Q
Questionable value, including out of range values
CRS_MIN - numeric(5,1) (ratio)
ID: MS04803.CRS_MIN
Minimum air temperature measurement for a 5-minute interval sampled by a Campbell Scientific model 107 thermistor housed in a NovaLynx 380-605 large instrument (cotton region) shelter at 150 cm height
Type system: Microsoft SQL Server 2008
Unit: degrees Celsius
Precision: 1
Numeric domain: type=real, min=-94.2000 (exclusive=false), max=41.5000 (exclusive=false)
CRS_MIN_FLAG - char(1) (nominal)
ID: MS04803.CRS_MIN_FLAG
Rows flagged for QA issues, including missing and out of range values
Type system: Microsoft SQL Server 2008
Code definitions (3)
-
A
Accepted value has passed all QC tests applied as represented by the quality level
-
M
Missing value
-
Q
Questionable value, including out of range values
GILL_MEAN - numeric(5,1) (ratio)
ID: MS04803.GILL_MEAN
Mean air temperature measurement for interval sampled by a Campbell Scientific model 107 thermistor housed in a R.M. Young 41303-5A 6-plate radiation shield at 150 cm height
Type system: Microsoft SQL Server 2008
Unit: degrees Celsius
Precision: 1
Numeric domain: type=real, min=-13.6000 (exclusive=false), max=74.2000 (exclusive=false)
GILL_MEAN_FLAG - char(1) (nominal)
ID: MS04803.GILL_MEAN_FLAG
Rows flagged for QA issues, including missing and out of range values
Type system: Microsoft SQL Server 2008
Code definitions (3)
-
A
Accepted value has passed all QC tests applied as represented by the quality level
-
M
Missing value
-
Q
Questionable value, including out of range values
GILL_MAX - numeric(5,1) (ratio)
ID: MS04803.GILL_MAX
Maximum air temperature measurement for a 5-minute interval sampled by a Campbell Scientific model 107 thermistor housed in a R.M. Young 41303-5A 6-plate radiation shield at 150 cm height
Type system: Microsoft SQL Server 2008
Unit: degrees Celsius
Precision: 1
Numeric domain: type=real, min=-13.5000 (exclusive=false), max=68.4000 (exclusive=false)
GILL_MAX_FLAG - char(1) (nominal)
ID: MS04803.GILL_MAX_FLAG
Rows flagged for QA issues, including missing and out of range values
Type system: Microsoft SQL Server 2008
Code definitions (3)
-
A
Accepted value has passed all QC tests applied as represented by the quality level
-
M
Missing value
-
Q
Questionable value, including out of range values
GILL_MIN - numeric(5,1) (ratio)
ID: MS04803.GILL_MIN
Minimum air temperature measurement for a 5-minute interval sampled by a Campbell Scientific model 107 thermistor housed in a R.M. Young 41303-5A 6-plate radiation shield at 150 cm height
Type system: Microsoft SQL Server 2008
Unit: degrees Celsius
Precision: 1
Numeric domain: type=real, min=-38.0000 (exclusive=false), max=41.3000 (exclusive=false)
GILL_MIN_FLAG - char(1) (nominal)
ID: MS04803.GILL_MIN_FLAG
Rows flagged for QA issues, including missing and out of range values
Type system: Microsoft SQL Server 2008
Code definitions (3)
-
A
Accepted value has passed all QC tests applied as represented by the quality level
-
M
Missing value
-
Q
Questionable value, including out of range values
HJA_MEAN - numeric(5,1) (ratio)
ID: MS04803.HJA_MEAN
Mean air temperature measurement for interval sampled by a Campbell Scientific model 107 thermistor housed in a locally designed radiation shield at 150 cm height (8-inch long, 3.5 inch diameter, schedule 40 PVC pipe split in half lengthwise
Type system: Microsoft SQL Server 2008
Unit: degrees Celsius
Precision: 1
Numeric domain: type=real, min=-14.0000 (exclusive=false), max=43.1000 (exclusive=false)
HJA_MEAN_FLAG - char(1) (nominal)
ID: MS04803.HJA_MEAN_FLAG
Rows flagged for QA issues, including missing and out of range values
Type system: Microsoft SQL Server 2008
Code definitions (3)
-
A
Accepted value has passed all QC tests applied as represented by the quality level
-
M
Missing value
-
Q
Questionable value, including out of range values
HJA_MAX - numeric(5,1) (ratio)
ID: MS04803.HJA_MAX
Maximum air temperature measurement for a 5-minute interval sampled by a Campbell Scientific model 107 thermistor housed in a locally designed radiation shield at 150 cm height (8-inch long, 3.5 inch diameter, schedule 40 PVC pipe split in half lengthwis
Type system: Microsoft SQL Server 2008
Unit: degrees Celsius
Precision: 1
Numeric domain: type=real, min=-13.9000 (exclusive=false), max=43.5000 (exclusive=false)
HJA_MAX_FLAG - char(1) (nominal)
ID: MS04803.HJA_MAX_FLAG
Rows flagged for QA issues, including missing and out of range values
Type system: Microsoft SQL Server 2008
Code definitions (3)
-
A
Accepted value has passed all QC tests applied as represented by the quality level
-
M
Missing value
-
Q
Questionable value, including out of range values
HJA_MIN - numeric(5,1) (ratio)
ID: MS04803.HJA_MIN
Minimum air temperature measurement for a 5-minute interval sampled by a Campbell Scientific model 107 thermistor housed in a locally designed radiation shield at 150 cm height (8-inch long, 3.5 inch diameter, schedule 40 PVC pipe split in half lengthwis
Type system: Microsoft SQL Server 2008
Unit: degrees Celsius
Precision: 1
Numeric domain: type=real, min=-109.0000 (exclusive=false), max=42.8000 (exclusive=false)
HJA_MIN_FLAG - char(1) (nominal)
ID: MS04803.HJA_MIN_FLAG
Rows flagged for QA issues, including missing and out of range values
Type system: Microsoft SQL Server 2008
Code definitions (3)
-
A
Accepted value has passed all QC tests applied as represented by the quality level
-
M
Missing value
-
Q
Questionable value, including out of range values
MS04804 - MS04804
Object name: MS04804.csv
Records: 232174
Attributes: 16
Temporal coverage: 2015-02-10 to 2017-04-01
File size: 15835549 byte
Checksum (MD5): 4e1e632c78a5c2c320b73c72ed20e763
Format: headers=1, recordDelimiter=\r\n, fieldDelimiter=,, quoteCharacter=", orientation=column
Constraints (2)
-
primaryKey: PRIMARY MS04804.DATE_TIME, MS04804.SITE
-
notNullConstraint: NOTNULL MS04804.DATE_TIME, MS04804.DBCODE, MS04804.ENTITY, MS04804.REF_SOLAR_MAX_FLAG, MS04804.REF_SOLAR_MEAN_FLAG, MS04804.SITE, MS04804.SOLAR_MAX_FLAG, MS04804.SOLAR_MEAN_FLAG, MS04804.WSPD_MAX_FLAG, MS04804.WSPD_MEAN_FLAG
Attributes (16)
DBCODE - char(5) (nominal)
ID: MS04804.DBCODE
FSDB Database Code (MS048)
Type system: Microsoft SQL Server 2008
Code definitions (1)
-
MS048
FSDB Database Study Code
ENTITY - numeric(2,0) (ratio)
ID: MS04804.ENTITY
Entity number
Type system: Microsoft SQL Server 2008
Unit: number
Precision: 1
Numeric domain: type=natural, min=4.0000 (exclusive=false), max=4.0000 (exclusive=false)
SITE - char(6) (ordinal)
ID: MS04804.SITE
Site where data collected
Type system: Microsoft SQL Server 2008
Code definitions (1)
-
PRIMET
Primary Meteorological Station
DATE_TIME - datetime (dateTime)
ID: MS04804.DATE_TIME
Date and time collected
Type system: Microsoft SQL Server 2008
Date format: YYYY-MM-DD hh:mm:ss
SOLAR_MEAN - numeric(4,0) (ratio)
ID: MS04804.SOLAR_MEAN
Mean incoming solar radiation for interval is measured by a Kipp and Zonen solar radiation pyranometer, model CM3, with a Campbell Scientific data logger at 150 cm height
Type system: Microsoft SQL Server 2008
Unit: watt per m2
Precision: 1
Numeric domain: type=real, min=0.0000 (exclusive=false), max=1222.0000 (exclusive=false)
SOLAR_MEAN_FLAG - char(1) (nominal)
ID: MS04804.SOLAR_MEAN_FLAG
Rows flagged for QA issues, including missing and out of range values
Type system: Microsoft SQL Server 2008
Code definitions (3)
-
A
Accepted value has passed all QC tests applied as represented by the quality level
-
M
Missing value
-
Q
Questionable value, including out of range values
SOLAR_MAX - numeric(4,0) (ratio)
ID: MS04804.SOLAR_MAX
Maximum incoming solar radiation for a 5-minute interval is measured by a Kipp and Zonen solar radiation pyranometer, model CM3, with a Campbell Scientific data logger at 150 cm height
Type system: Microsoft SQL Server 2008
Unit: watt per m2
Precision: 1
Numeric domain: type=real, min=0.0000 (exclusive=false), max=1384.0000 (exclusive=false)
SOLAR_MAX_FLAG - char(1) (nominal)
ID: MS04804.SOLAR_MAX_FLAG
Rows flagged for QA issues, including missing and out of range values
Type system: Microsoft SQL Server 2008
Code definitions (3)
-
A
Accepted value has passed all QC tests applied as represented by the quality level
-
M
Missing value
-
Q
Questionable value, including out of range values
REF_SOLAR_MEAN - numeric(3,0) (ratio)
ID: MS04804.REF_SOLAR_MEAN
Mean reflected solar radiation for interval is measured by a downward-facing Kipp and Zonen solar radiation pyranometer, model CM3, with a Campbell Scientific data logger at 150 cm height
Type system: Microsoft SQL Server 2008
Unit: watt per m2
Precision: 1
Numeric domain: type=real, min=0.0000 (exclusive=false), max=475.0000 (exclusive=false)
REF_SOLAR_MEAN_FLAG - char(1) (nominal)
ID: MS04804.REF_SOLAR_MEAN_FLAG
Rows flagged for QA issues, including missing and out of range values
Type system: Microsoft SQL Server 2008
Code definitions (3)
-
A
Accepted value has passed all QC tests applied as represented by the quality level
-
M
Missing value
-
Q
Questionable value, including out of range values
REF_SOLAR_MAX - numeric(4,0) (ratio)
ID: MS04804.REF_SOLAR_MAX
Maximum reflected solar radiation for a 5-minute interval is measured by a downward-facing Kipp and Zonen solar radiation pyranometer, model CM3, with a Campbell Scientific data logger at 150 cm height
Type system: Microsoft SQL Server 2008
Unit: watt per m2
Precision: 1
Numeric domain: type=real, min=0.0000 (exclusive=false), max=479.0000 (exclusive=false)
REF_SOLAR_MAX_FLAG - char(1) (nominal)
ID: MS04804.REF_SOLAR_MAX_FLAG
Rows flagged for QA issues, including missing and out of range values
Type system: Microsoft SQL Server 2008
Code definitions (3)
-
A
Accepted value has passed all QC tests applied as represented by the quality level
-
M
Missing value
-
Q
Questionable value, including out of range values
WSPD_MEAN - numeric(3,1) (ratio)
ID: MS04804.WSPD_MEAN
Mean wind speed for interval is measured by an RM Young Model 05103 Wind Monitor mounted to the tower at 150 cm with a Campbell Scientific data logger.
Type system: Microsoft SQL Server 2008
Unit: meters per second
Precision: 1
Numeric domain: type=real, min=0.0000 (exclusive=false), max=18.0000 (exclusive=false)
WSPD_MEAN_FLAG - char(1) (nominal)
ID: MS04804.WSPD_MEAN_FLAG
Rows flagged for QA issues, including missing and out of range values
Type system: Microsoft SQL Server 2008
Code definitions (5)
-
A
Accepted value has passed all QC tests applied as represented by the quality level
-
M
Missing value
-
Q
Questionable value, including out of range values
-
B
Wind speed measurement is below or equal to the instrument detection limit of 1 m per second
-
NB
Wind speed measurement is below or equal to 0.3 m per second and is not considered reliable and is below the instrument detection limit of 1 m per second
WSPD_MAX - numeric(3,1) (ratio)
ID: MS04804.WSPD_MAX
Maximum wind speed for a 5-minute interval is measured by an RM Young Model 05103 Wind Monitor mounted to the tower at 150 cm with a Campbell Scientific data logger.
Type system: Microsoft SQL Server 2008
Unit: meters per second
Precision: 1
Numeric domain: type=real, min=0.0000 (exclusive=false), max=18.0000 (exclusive=false)
WSPD_MAX_FLAG - char(1) (nominal)
ID: MS04804.WSPD_MAX_FLAG
Rows flagged for QA issues, including missing and out of range values
Type system: Microsoft SQL Server 2008
Code definitions (5)
-
A
Accepted value has passed all QC tests applied as represented by the quality level
-
M
Missing value
-
Q
Questionable value, including out of range values
-
B
Wind speed measurement is below or equal to the instrument detection limit of 1 m per second
-
NB
Wind speed measurement is below or equal to 0.3 m per second and is not considered reliable and is below the instrument detection limit of 1 m per second
Units
| degrees Celsius | deg c | temperature | celsiusDegree | kelvin | 1 | Degrees Celsius; a common unit of temperature; constantToSI=273.18 |
| number | number | dimensionless | number | dimensionless | 1 | dimensionless number, i.e., ratio, count |
| watt per m2 | W/m2 | powerDensity | wattPerMeterSquared | joulePerMeterSquared | 1 | watt per meter squared |
| meters per second | m/sec | speed | meterPerSecond | meterPerSecond | 1 | meters per second |
Intellectual Rights
Data Use Agreement:
The re-use of scientific data has the potential to greatly increase communication, collaboration and synthesis within and among disciplines, and thus is fostered, supported and encouraged. This Data Set is released under the Creative Commons license CC BY "Attribution" (see: https://creativecommons.org/licenses/by/4.0/). Creative Commons license CC BY - Attribution is a license that allows others to distribute, remix, tweak, and build upon your work (even commercially), as long as you are credited for the original creation. This license accommodates maximum dissemination and use of licensed materials.
It is considered professional conduct and an ethical obligation to acknowledge the work of other scientists. The Data User is asked to provide attribution of the original work if this data package is shared in whole or by individual parts or used in the derivation of other products. A recommended citation is provided for each Data Set in the Andrews LTER data catalog (see: http://andlter.forestry.oregonstate.edu/data/catalog/datacatalog.aspx). A generic citation is also provided for this Data Set on the website https://portal.edirepository.org in the summary metadata page. Data Users are thus strongly encouraged to consider consultation, collaboration and/or co-authorship with the Data Set Creator.
While substantial efforts are made to ensure the accuracy of data and associated documentation, complete accuracy of data sets cannot be guaranteed and all data are made available "as is." The Data User should be aware, however, that data are updated periodically and it is the responsibility of the Data User to check for new versions of the data. The data authors and the repository where these data were obtained shall not be liable for damages resulting from any use or misinterpretation of the data.
General acknowledgement: Data were provided by the HJ Andrews Experimental Forest research program, funded by the National Science Foundation's Long-Term Ecological Research Program (DEB 1440409), US Forest Service Pacific Northwest Research Station, and Oregon State University.
Licensed
License: N/A
Maintenance
Maintenance update frequency: notPlanned
Description
- An update history is logged and maintained with each new version of every dataset.
Change History
-
Version1 (2019-09-27) Study code and preliminary metadata established
-
Version2 (2020-10-21) Data passed QC and is ready to upload to PASTA